BCV method helps estimate clusters and hyper-parameters in large data sets.
problem Determining the number of clusters in large-scale data.
method Bi-cross validation (BCV) for spectral clustering.
result BCV directly applies to spectral clustering for estimating clusters and hyper-parameters.
X-ray free-electron lasers (XFELs) are the only sources currently able to produce bright few-fs pulses with tunable photon energies from 100 eV to more than 10 keV. Due to the stochastic SASE operating principles and other technical issues the output pulses are subject to large fluctuations, making it necessary to char…
System helps scientists visualize deep learning model of x-ray images.
problem Understanding complex x-ray scattering images with multiple attributes.
method Interactive visualization system in feature space and classification output.
result Users can explore and compare images and attributes flexibly.
Stability of non-abelian X-ray transform proven in higher dimensions.
problem Recovering matrix potentials from scattering data in higher dimensions.
method Injectivity proof using a novel method by Uhlmann-Vasy, with quantitative improvements.
result Hölder-type stability estimate established for non-abelian X-ray transform.
Study scattering rigidity for Hamiltonian systems, proving lens rigidity for non-trapping Finsler manifolds.
problem Scattering rigidity for Hamiltonian systems on manifolds with boundary.
method Linearization of travel times, X-ray transform over Hamiltonian curves, Hamiltonian light ray transform.
result Prove semiglobal lens rigidity of non-trapping Finsler manifolds.
Current Flash X-ray single-particle diffraction Imaging (FXI) experiments, which operate on modern X-ray Free Electron Lasers (XFELs), can record millions of interpretable diffraction patterns from individual biomolecules per day. Due to the stochastic nature of the XFELs, those patterns will to a varying degree includ…
Study travel time tomography for transversely isotropic media using modified pseudodifferential calculus.
problem Travel time tomography problem for transversely isotropic media.
method Modified scattering pseudodifferential calculus to solve the tomography problem.
result Construction and use of modified pseudodifferential calculus to solve the tomography problem.
Consider a compact Riemannian manifold of dimension ≥3 with strictly convex boundary, such that the manifold admits a strictly convex function. We show that the attenuated ray transform in the presence of an arbitrary connection and Higgs field is injective modulo the natural obstruction for functions and one-for…
New method finds all thin film structures from reflectometry data.
problem Computational prohibitive for standard algorithms, leading to unreliable analysis.
method Prior-Amortized Neural Posterior Estimation (PANPE) combining simulation-based inference and adaptive priors.
result Identifies all realistic structures in seconds, setting new standards in reflectometry.
We consider solutions to the anti-self-dual Yang Mills (ASDYM) equations in split signature that are global on the double cover of the appropriate conformally compactified Minkowski space $\widetilde\M$. Ward's ASDYM twistor construction is adapted to this geometry by using a correspondence between points of $\widetild…
In this paper, we show how to construct graph theoretical models of n-dimensional continuous objects and manifolds. These models retain topological properties of their continuous counterparts. An LCL collection of n-cells in Euclidean space is introduced and investigated. If an LCL collection of n-cells is a cover of a…
Sharp mapping properties and regularization for X-ray transform on disks of constant curvature.
problem Sharp mapping properties and regularization of X-ray transform.
method Derive functional relations and mapping properties using elliptic differential operators.
result Theoretical possibility of regularized inversions for X-ray transform.
Regularity results for geodesic X-ray transform on nonsmooth manifolds
problem Geodesic X-ray transform on nonsmooth simple manifolds
method Symbol smoothing arguments and pseudodifferential operators with low regularity symbols
result Improved injectivity results for Lp functions Local X-ray transform works well near boundaries in hyperbolic spaces.
problem Injectivity of X-ray transform near boundaries for hyperbolic metrics.
method Local injectivity proof for geodesic X-ray transform on asymptotically hyperbolic manifolds.
result Local injectivity near a boundary point for X-ray transform in dimensions 3 and higher, up to O(ρ5). Paper shows invertibility of tensor X-ray transform on certain manifolds.
problem Invertibility of tensor X-ray transform on asymptotically conic manifolds.
method Used 1-cusp pseudodifferential operator algebra and modified solenoidal gauge condition.
result Invertibility of tensor X-ray transform up to natural obstruction.
Study shows stability in X-ray transform on specific hyperbolic manifolds.
problem Stability of X-ray transform on asymptotically hyperbolic manifolds.
method Constructed a parametrix for the normal operator in 0-pseudodifferential calculus.
result Showed a stability estimate for the X-ray transform.
Study X-ray transform on conic spaces, proving injectivity under certain conditions.
problem Injectivity of geodesic X-ray transform on conic metrics.
method Injectivity under non-trapping and no conjugate point assumptions.
result Injectivity of geodesic X-ray transform for asymptotically conic metrics.
Injective X-ray transform on Heisenberg group for regular functions.
problem Injectivity of X-ray transform on sub-Riemannian manifolds.
method Group Fourier Transform and analysis of taming metrics.
result Sufficiently regular functions on Heisenberg group are determined by their line integrals.
Paper proves injectivity of non-abelian X-ray transform on certain spaces.
problem Injectivity of non-abelian X-ray transform on asymptotically hyperbolic spaces.
method Gauge equivalence for unitary connections and skew-Hermitian Higgs fields.
result Injectivity result for non-abelian X-ray transform over skew-Hermitian Higgs fields.
Early results in using convolutional neural networks (CNNs) on x-rays to diagnose disease have been promising, but it has not yet been shown that models trained on x-rays from one hospital or one group of hospitals will work equally well at different hospitals. Before these tools are used for computer-aided diagnosis i…
X-rays are commonly performed imaging tests that use small amounts of radiation to produce pictures of the organs, tissues, and bones of the body. X-rays of the chest are used to detect abnormalities or diseases of the airways, blood vessels, bones, heart, and lungs. In this work we present a stochastic attention-based…
Deep-learning method estimates bone 3D structure from X-ray images.
problem Estimating bone 3D structure from X-ray images.
method Triplet loss-trained neural network selecting closest 3D bone shape from predefined set.
result Average RMS distance of 1.08 mm between predicted and true shapes.
X-ray transform on H-type groups solved, revealing function injectivity.
problem Injectivity in sub-Riemannian geometry.
method Fourier Slice Theorem adapted to H-type groups.
result Integrable functions on H-type groups are uniquely determined by their integrals over geodesics.
New method eliminates domain size restrictions for X-ray transform inversion.
problem Injectivity and stability of X-ray transform in convex domains.
method Semiclassical analysis to invert X-ray transform without small domain assumptions.
result Elimination of domain size restrictions for injectivity and stability.
Study improves deep learning chest X-ray models by incorporating lateral views.
problem Lack of lateral views in training datasets limits deep learning performance.
method Used PadChest dataset with multiple views to explore merging methods.
result Incorporating lateral views increases model performance for 32 labels.
Study proper sampling for X-ray transforms on simple surfaces.
problem Proper discretizing and sampling issues related to geodesic X-ray transforms on simple surfaces.
method Provide minimal sampling rates for faithful reconstruction, quantify sampling quality, and predict artifacts.
result Minimal sampling rates and artifact prediction for geodesic X-ray transforms on simple surfaces.
FRODO method rejects out-of-distribution chest x-ray images with high accuracy.
problem Rejecting out-of-distribution samples in medical image analysis.
method Uses feature activations and Mahalanobis distance to measure distribution mismatch.
result Achieves an AUC score of 0.99 in classifying chest x-ray images as in or out of distribution.
Paper solves injectivity of X-ray transform on surfaces.
problem Injectivity of non-Abelian X-ray transform on surfaces.
method Factorization theorem for Loop Groups, energy methods, scalar holomorphic integrating factors.
result Extends results to arbitrary Lie groups.
New proof of injectivity for broken non-abelian X-ray transform in Minkowski space.
problem Injectivity of broken non-abelian X-ray transform in Minkowski space.
method Stability estimate considering gauge, light-sink connections, Bayesian inversion.
result Consistent recovery of light-sink connections from noisy data.
Enhanced X-ray polarimetry with deep learning for better exposure times.
problem Improving sensitivity of X-ray telescopic observations with imaging polarimeters.
method A weighted maximum likelihood combination of predictions from a deep ensemble of ResNet convolutional neural networks trained on Monte Carlo event simulations.
result Improves effective exposure times by ~45% for power-law source spectra.
These are lecture notes for the course "Analysis and X-ray tomography". The course is a broad overview of various tools in analysis that can be used to study X-ray tomography. The focus is on tools and ideas, not so much on technical details and minimal assumptions. Only very basic functional analysis is assumed as bac…
Study X-ray transform on manifolds, desingularize, and improve mapping properties.
problem Characterize mapping properties of X-ray transform and its adjoint on manifolds with strictly convex boundary.
method Use b-fibrations, desingularize, and apply Melrose's Pushforward Theorem to analyze polyhomogeneous functions.
result Improved mapping properties of X-ray transform and its adjoint, recovering sharp results.
We show that the existence of a function in L1 with constant geodesic X-ray transform imposes geometrical restrictions on the manifold. The boundary of the manifold has to be umbilical and in the case of a strictly convex Euclidean domain, it must be a ball. Functions with constant geodesic X-ray transform always …
Unique continuation for X-ray transforms of one-forms with partial data.
problem Proving unique continuation for X-ray transforms of one-forms with limited data.
method Proved unique continuation for the normal operator of X-ray transforms of one-forms, leading to partial data results.
result Unique continuation for X-ray transforms of one-forms with partial data.
Guillarmou extends X-ray transform to magnetic and thermostat flows.
problem Stability of magnetic X-ray transforms.
method Generalizes normal operator to thermostat and magnetic flows, proving ellipticity.
result Elliptic pseudodifferential operators of order -1 for generalized normal operators.
New insights into X-ray transform on hyperbolic disk, with functional relations and range characterizations.
problem Understanding the X-ray transform on hyperbolic geometry.
method Derived new singular value decompositions, range characterizations, and intertwining relations with wedge-type differential operators.
result Sharp understanding of boundary behavior and invertibility settings for the X-ray transform.
Novel semi-supervised method for X-ray classification with minimal labels.
problem Classifying X-ray data with limited labeled data.
method Graph-based semi-supervised learning with carefully selected class priors.
result Competitive results on ChestX-ray14 data set with reduced need for annotated data.
Paper shows X-ray transform invertible on certain curved spaces.
problem Invertibility of X-ray transform on curved spaces.
method Introduced new pseudodifferential operator algebra for analysis.
result Stable invertibility near infinity on asymptotically conic manifolds.
Among the plethora of techniques devised to curb the prevalence of noise in medical images, deep learning based approaches have shown the most promise. However, one critical limitation of these deep learning based denoisers is the requirement of high-quality noiseless ground truth images that are difficult to obtain in…
We develop an algorithm that can detect pneumonia from chest X-rays at a level exceeding practicing radiologists. Our algorithm, CheXNet, is a 121-layer convolutional neural network trained on ChestX-ray14, currently the largest publicly available chest X-ray dataset, containing over 100,000 frontal-view X-ray images w…
The geodesic X-ray transform on disks of constant curvature is characterized and decomposed.
problem Characterizing and decomposing the geodesic X-ray transform on disks of constant curvature.
method Explicit construction of a basis for the range and co-kernel, derivation of Singular Value Decomposition.
result Explicit Singular Value Decomposition for the geodesic X-ray transform.
This study evaluates adversarial attacks and defenses for chest X-ray disease classification.
problem Vulnerability of deep neural networks to adversarial examples in chest X-ray disease detection.
method Detailed introduction and evaluation of various attack and defense methods.
result Attack and defense methods perform poorly with excessive iterations and large perturbations.
Injectivity of geodesic X-ray transform on low-regularity manifolds.
problem Injectivity of geodesic X-ray transform on manifolds with low regularity.
method Calculus of differential and curvature operators on non-smooth structures.
result Injectivity of geodesic X-ray transform on simple Riemannian manifolds with C1,1-regularity. We complete the microlocal study of the geodesic X-ray transform on Riemannian manifolds with Anosov geodesic flow initiated by Guillarmou and pursued by Guillarmou and the second author. We prove new stability estimates and clarify some properties of the operator Πm, the generalized X-ray transform. These estimates…
Suppressing bones on chest X-rays such as ribs and clavicle is often expected to improve pathologies classification. These bones can interfere with a broad range of diagnostic tasks on pulmonary disease except for musculoskeletal system. Current conventional method for acquisition of bone suppressed X-rays is dual ener…
Statistical image reconstruction (SIR) methods are studied extensively for X-ray computed tomography (CT) due to the potential of acquiring CT scans with reduced X-ray dose while maintaining image quality. However, the longer reconstruction time of SIR methods hinders their use in X-ray CT in practice. To accelerate st…
The MIMIC-CXR dataset is (to date) the largest released chest x-ray dataset consisting of 473,064 chest x-rays and 206,574 radiology reports collected from 63,478 patients. We present the results of training and evaluating a collection of deep convolutional neural networks on this dataset to recognize multiple common t…
Injectivity of X-ray transform proven for non-smooth metrics.
problem Injectivity of X-ray transform on non-smooth metrics.
method Microlocal analysis of the normal operator, establishing ellipticity and smoothing properties.
result Injectivity of X-ray transform on L2 for metrics with finitely differentiable tensor.