Research
On-device research index

arXiv research

A locally-built, LLM-digested index of recent arXiv papers in quant finance, geometry/topology, and statistical ML — keyword search served straight from SQLite on this machine.

168,742 papers · 148 categories

Trend · papers per month

471114 · Nov 201819922001200920172026
48 results for Heart arrhythmia

We consider the problem of locating a point-source heart arrhythmia using data from a standard diagnostic procedure, where a reference catheter is placed in the heart, and arrival times from a second diagnostic catheter are recorded as the diagnostic catheter moves around within the heart. We model this situation as a …

2018-07-09abs ↗pdf ↗

Improved robustness of 1D CNNs for heart arrhythmia classification.

problem Improving the robustness of 1D CNNs for classification tasks.
method Parameterization using Cayley transform and controllability Gramian for Lipschitz-bounded CNNs.
result Improved robustness of trained Lipschitz-bounded 1D CNNs for heart arrhythmia classification.

DeepBeat uses deep learning to assess signal quality and detect arrhythmia in wearable devices.

problem Detecting atrial fibrillation from wearable devices with noise.
method Multi-task deep learning approach using convolutional denoising autoencoders.
result Significantly improved AF detection accuracy compared to traditional methods.

Generative adversarial network system improves ECG arrhythmia classification.

problem Improving automatic ECG arrhythmia classification accuracy.
method Generative adversarial network with patient-specific normal beats and generated abnormal beats.
result Superior overall classification performance for SVEB and VEB on MIT-BIH arrhythmia database.

A new method reduces the computational cost of Sinkhorn algorithm for OT and UOT problems.

problem High computational complexity of Sinkhorn algorithm for OT and UOT problems.
method Importance sparsification method called Spar-Sink to efficiently approximate entropy-regularized OT and UOT solutions.
result The method reduces computational cost from O(n2)O(n^2) to O~(n)\widetilde{O}(n), and is consistent under mild regularity conditions.

Improved cardiac arrhythmia detection in wearable devices with neural networks.

problem Resource constraints in low-power wearable devices for accurate arrhythmia detection.
method Adapted a convolutional-recurrent neural network to a low-power microcontroller, optimizing for precision and memory usage.
result Reduced F1F_1 score from 0.8 to 0.784 in fixed-point precision, with a 195.6KB memory footprint and 33.98MOps/s throughput.

Electrocardiogram (ECG) can be reliably used as a measure to monitor the functionality of the cardiovascular system. Recently, there has been a great attention towards accurate categorization of heartbeats. While there are many commonalities between different ECG conditions, the focus of most studies has been classifyi…

2018-04-19abs ↗pdf ↗

Framework for imputing missing heart data to simulate brain-heart interactions.

problem Lack of multi-modal patient data representing heart and brain processes.
method Probabilistic framework for joint cardiac data imputation and mechanistic model personalization.
result Accurate imputation of missing cardiac features in incomplete datasets.

Improved heart rate and activity recognition with low-power wrist sensors.

problem Challenges in battery life, cost, and sensor performance in wrist-worn sensing applications.
method Used photoplethysmography (PPG) for heart rate and activity recognition, applying transfer learning and CNNs.
result Low sampling frequencies (5 Hz and 10 Hz) achieved good performance in heart rate and activity recognition.

Heart disease is the leading cause of death, and experts estimate that approximately half of all heart attacks and strokes occur in people who have not been flagged as "at risk." Thus, there is an urgent need to improve the accuracy of heart disease diagnosis. To this end, we investigate the potential of using data ana…

2018-08-22abs ↗pdf ↗

Continuous, ubiquitous monitoring through wearable sensors has the potential to collect useful information about users' context. Heart rate is an important physiologic measure used in a wide variety of applications, such as fitness tracking and health monitoring. However, wearable sensors that monitor heart rate, such …

2019-12-18abs ↗pdf ↗

Proposes a novel anomaly detection method for echocardiogram videos.

problem Anomaly detection in echocardiogram videos.
method Dynamic Variational Trajectory Models (TVAE-C, TVAE-R, TVAE-S) trained on healthy infant echocardiogram videos.
result Superior performance in detecting congenital heart defects and pulmonary hypertension.

This paper explores four different visualization techniques for long short-term memory (LSTM) networks applied to continuous-valued time series. On the datasets analysed, we find that the best visualization technique is to learn an input deletion mask that optimally reduces the true class score. With a specific focus o…

2017-05-23abs ↗pdf ↗

AI-assisted heart disease diagnosis reduces misdiagnosis and saves lives.

problem Misdiagnosis of heart disease leads to unnecessary deaths.
method Developed an AI application using ML and DNN algorithms on a dataset from the Cleveland Clinic Foundation.
result DNN model achieved a 92% accuracy rate, reducing misdiagnosis.

Study predicts heart failure patient survival using stacked ensemble ML.

problem Predicting survival of heart failure patients.
method Collect and analyze patient data, apply SMOTE, use K-Means, Fuzzy C-Means clustering, Random Forest, XGBoost, Decision Tree, and propose a stacked ensemble model.
result Supervised ML algorithms outperform unsupervised models, achieving high accuracy and F1 score.

Cardiovascular Disease (CVD) is considered as one of the principal causes of death in the world. Over recent years, this field of study has attracted researchers' attention to investigate heart sounds' patterns for disease diagnostics. In this study, an approach is proposed for normal/abnormal heart sound classificatio…

2019-04-26abs ↗pdf ↗

Study examines heart and football-shaped metrics, verifying geometric structure.

problem Analyzing reducible spherical conical metrics and their geometric properties.
method Examined 1-parameter heart shape and 3-parameter football shape families, verified structure theorem, used explicit metric and geodesic calculations.
result Naturally arise from Abelian differentials of the third kind, offer new evidence for spherical geometry and complex analytic structure interaction.

The study examines machine learning classification algorithms and their generalizability using Framingham Heart Study data.

problem Addressing biases and generalizability issues in machine learning classification algorithms.
method Comparison of eight machine learning classification algorithms on Framingham Heart Study data.
result Double discriminant scoring of type I is the most generalizable algorithm.

Personalized deep learning reduces inappropriate shocks in VA detection.

problem High inappropriate shock rate in traditional VA detection methods.
method Personalized deep learning framework using CNN for real-time VA detection and collaborative inference.
result 6.6% reduction in inappropriate shock rate compared to traditional methods.

Machine learning improves CHD screening accuracy from 70% to 87.7%.

problem Predicting coronary heart disease using echocardiography and clinical features.
method Ensemble machine learning approach with model stacking and two-step stacking.
result Improved CHD classification accuracy from 70% to 87.7%.

New scalable method balances hospital profit status and heart attack outcomes.

problem Balancing covariate distributions and minimizing weight dispersion in large datasets.
method Combines kernel basis expansion and convex optimization for efficient and flexible weighting.
result For-profit hospitals use interventional cardiology similarly to other hospitals but have higher mortality and readmission rates.