Research
On-device research index

arXiv research

A locally-built, LLM-digested index of recent arXiv papers in quant finance, geometry/topology, and statistical ML — keyword search served straight from SQLite on this machine.

168,742 papers · 148 categories

Trend · papers per month

21416282 · Jun 202019922001200920172026
48 results for Accelerated MRI

Deep learning improves MRI image quality from down-sampled data.

problem Improving MRI image quality from accelerated, down-sampled k-space data.
method Deep Residual Dense U-Net architecture with Residual Dense Block and new loss function.
result The proposed method achieves better performance in reconstructing high-quality images from down-sampled k-space data.

Accelerating Magnetic Resonance Imaging (MRI) by taking fewer measurements has the potential to reduce medical costs, minimize stress to patients and make MRI possible in applications where it is currently prohibitively slow or expensive. We introduce the fastMRI dataset, a large-scale collection of both raw MR measure…

2018-11-21abs ↗pdf ↗

In compressed sensing MRI (CS-MRI), k-space measurements are under-sampled to achieve accelerated scan times. CS-MRI presents two fundamental problems: (1) where to sample and (2) how to reconstruct an under-sampled scan. In this paper, we tackle both problems simultaneously for the specific case of 2D Cartesian sampli…

2019-07-26abs ↗pdf ↗

Enhances deep neural networks for MRI reconstruction by increasing expressivity.

problem Balancing network complexity and performance in deep learning MRI reconstruction.
method Geometric approach using bootstrapping and subnetwork aggregation with attention module.
result Significant improvement in MRI reconstruction performance with minimal complexity increase.

This study uses CNN-IOs to estimate MRI image reconstruction performance bounds.

problem Estimating task-based performance limits for MRI image reconstruction methods.
method Utilized stylized multi-coil SENSE MRI systems and deep-generated stochastic models to estimate IO performance.
result Estimation of IO performance provides guidance for designing under-sampled MRI systems.

Improves MRI-based brain surface reconstruction with minimal deformation energy loss.

problem Ensuring optimal deformation energy and consistency in learning-based cortical surface reconstruction.
method Design and implementation of a Minimal Energy Deformation (MED) loss in the V2C-Flow model.
result Significant improvements in training consistency and reproducibility without sacrificing reconstruction accuracy and topological correctness.

Ensembled neural networks improve MRI image quality.

problem Accelerated parallel MR imaging with high SSIM scores.
method Ensembled ΣΣ-net combining parallel coil and sensitivity networks, trained with supervised and semi-supervised methods.
result Ensembling models achieves visually sharp and textured images with robust SSIM scores.

Deep-SLR reduces SLR complexity with CNN, enabling efficient parallel MRI.

problem High computational complexity in SLR matrix completion.
method Convolutional Neural Network (CNN) trained to estimate annihilation relations from imperfect k-space measurements.
result Significant reduction in runtime by three orders of magnitude compared to SLR schemes.

MosaicMRI expands public datasets for musculoskeletal MRI, revealing cross-anatomical correlations.

problem Limited diversity in public MRI datasets hinders model evaluation across different anatomical settings.
method Developed a large, diverse dataset (MosaicMRI) and conducted experiments on a baseline model (VarNet).
result Models trained on combined anatomies outperform anatomy-specific models in low-sample regimes.

Nyquist ghost artifacts in EPI are originated from phase mismatch between the even and odd echoes. However, conventional correction methods using reference scans often produce erroneous results especially in high-field MRI due to the non-linear and time-varying local magnetic field changes. Recently, it was shown that …

2018-06-01abs ↗pdf ↗

Acquisition of Magnetic Resonance Imaging (MRI) scans can be accelerated by under-sampling in k-space (i.e., the Fourier domain). In this paper, we consider the problem of optimizing the sub-sampling pattern in a data-driven fashion. Since the reconstruction model's performance depends on the sub-sampling pattern, we c…

2019-01-07abs ↗pdf ↗

PS-VAE extracts multi-parameter MRI biomarkers with uncertainty quantification.

problem Uncertainty in inverse problems limits clinical acceptance of quantitative MRI methods.
method Physics-Structured Variational Autoencoder (PS-VAE) integrating physics simulator and self-supervised learning.
result PS-VAE provides full covariance of inter-parameter correlations and accelerates multi-parametric MRI quantification.

Generative adversarial networks reconstruct MRI images without full data.

problem Lack of fully-sampled ground truth data for supervised MRI reconstruction.
method Generative adversarial networks for unsupervised MRI reconstruction.
result Reconstructed images show more anatomical structure than conventional methods.

New MRI method maps tissue parameters more accurately by ignoring voxel independence.

problem Voxel independence assumption limits model fitting reliability and repeatability.
method Self-supervised deep variational approach with Gaussian mixture prior.
result Our method outperforms current techniques in dMRI simulations and real data.

StaPLR improves Alzheimer's disease classification by identifying important MRI scan types and measures.

problem Classifying Alzheimer's disease using multi-source MRI data.
method Stacked penalized logistic regression (StaPLR) with hierarchical multi-view structure and new view importance measure.
result StaPLR identifies the most important MRI scan types and measures for Alzheimer's disease classification.

CCDF reduces diffusion sampling steps for inverse problems.

problem Slow sampling from diffusion models in inverse problems.
method Starting from a single forward diffusion step with better initialization, followed by stochastic contraction.
result Significantly reduced sampling steps for state-of-the-art reconstruction.

CSGM framework applied to clinical MRI data for robust reconstructions.

problem Applying deep generative priors to clinical MRI data for high-quality reconstructions.
method Training a generative prior on brain scans from the fastMRI dataset and using Langevin dynamics for posterior sampling.
result Posterior sampling via Langevin dynamics achieves high quality reconstructions in clinical MRI data.

This study improves lung tumor segmentation in mice MRI scans with nnU-Net, reducing annotation needs.

problem Accurate lung tumor segmentation in mice MRI scans for drug discovery.
method Optimized nnU-Net 3D model for lung tumor segmentation with minimal annotations.
result nnU-Net 3D models outperform 2D models in MRI mice scans, requiring fewer annotations.

New method MRI improves machine learning models' ability to generalize to unseen data.

problem Machine learning models often fail to generalize well to out-of-distribution data.
method Introduces a new notion of invariance (MRI) and a practical version (MRI-v1) to improve model generalization.
result MRI-v1 guarantees invariant predictors and outperforms IRM-v1 in various settings.

Machine learning for ASD diagnosis using morphological MRI networks.

problem Challenging to diagnose ASD using MRI due to heterogeneity and incomplete network neuroscience.
method Crowdsourced Kaggle competition to develop and benchmark ML pipelines.
result First-ranked team achieved 70% accuracy, 72.5% sensitivity, and 67.5% specificity.

A central question for active learning (AL) is: "what is the optimal selection?" Defining optimality by classifier loss produces a new characterisation of optimal AL behaviour, by treating expected loss reduction as a statistical target for estimation. This target forms the basis of model retraining improvement (MRI), …

2015-02-05abs ↗pdf ↗

Use expert visualization or conventional clinical indices can lack accuracy for borderline classications. Advanced statistical approaches based on eigen-decomposition have been mostly concerned with shape and motion indices. In this paper, we present a new approach to identify CVDs from cine-MRI by estimating large poo…

2019-09-25abs ↗pdf ↗

The annihilating filter-based low-rank Hankel matrix approach (ALOHA) is one of the state-of-the-art compressed sensing approaches that directly interpolates the missing k-space data using low-rank Hankel matrix completion. The success of ALOHA is due to the concise signal representation in the k-space domain thanks to…

2018-05-10abs ↗pdf ↗

Paper extends 2D ZSAD to 3D MRI without training, achieving robust anomaly detection.

problem Challenges in extending zero-shot anomaly detection to 3D medical images.
method Constructs localized volumetric tokens by aggregating 2D slices processed by 2D foundation models.
result Training-free, batch-based ZSAD effectively extends from 2D encoders to full 3D MRI volumes.

New unsupervised deep learning method improves temporal resolution in tMRA.

problem Limited temporal resolution in tMRA due to fixed view-sharing scheme.
method Optimal transport driven cycle-consistent generative adversarial network (cycleGAN) without fully sampled k-space reference data.
result Can generate high quality reconstructions at various temporal resolutions.

A method for MRI brain tumor segmentation using feature vectors and kernel dictionary learning.

problem Segmenting brain tumor regions in MRI images.
method Extracting feature vectors, training kernel dictionaries, and selecting informative feature vectors.
result The method outperforms other methods in segmentation accuracy and reduces training time.