A major challenge in computed tomography (CT) is to reduce X-ray dose to a low or even ultra-low level while maintaining the high quality of reconstructed images. We propose a new method for CT reconstruction that combines penalized weighted-least squares reconstruction (PWLS) with regularization based on a sparsifying…
arXiv research
A locally-built, LLM-digested index of recent arXiv papers in quant finance, geometry/topology, and statistical ML — keyword search served straight from SQLite on this machine.
Trend · papers per month
A major challenge in X-ray computed tomography (CT) is reducing radiation dose while maintaining high quality of reconstructed images. To reduce the radiation dose, one can reduce the number of projection views (sparse-view CT); however, it becomes difficult to achieve high-quality image reconstruction as the number of…
For homeland and transportation security applications, 2D X-ray explosive detection system (EDS) have been widely used, but they have limitations in recognizing 3D shape of the hidden objects. Among various types of 3D computed tomography (CT) systems to address this issue, this paper is interested in a stationary CT u…
The development of computed tomography (CT) image reconstruction methods that significantly reduce patient radiation exposure while maintaining high image quality is an important area of research in low-dose CT (LDCT) imaging. We propose a new penalized weighted least squares (PWLS) reconstruction method that exploits …
Breast CT provides image volumes with isotropic resolution in high contrast, enabling detection of small calcification (down to a few hundred microns in size) and subtle density differences. Since breast is sensitive to x-ray radiation, dose reduction of breast CT is an important topic, and for this purpose, few-view s…
Statistical image reconstruction (SIR) methods are studied extensively for X-ray computed tomography (CT) due to the potential of acquiring CT scans with reduced X-ray dose while maintaining image quality. However, the longer reconstruction time of SIR methods hinders their use in X-ray CT in practice. To accelerate st…
Deep-neural-network-based image reconstruction has demonstrated promising performance in medical imaging for under-sampled and low-dose scenarios. However, it requires large amount of memory and extensive time for the training. It is especially challenging to train the reconstruction networks for three-dimensional comp…
Obtaining accurate and reliable images from low-dose computed tomography (CT) is challenging. Regression convolutional neural network (CNN) models that are learned from training data are increasingly gaining attention in low-dose CT reconstruction. This paper modifies the architecture of an iterative regression CNN, BC…
Framework for confidence estimation in deep CT reconstructions.
This paper explores deep learning for improving X-ray CT image reconstruction from undersampled data.
A new model improves CT image quality from low-dose scans.
X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP) produces severe streaking artifacts. Recently, deep learning approaches using la…
A ML-based method reconstructs 3D organ doses from 2D radiographs for pediatric abdominal radiotherapy.
Method estimates uncertainty in CT reconstructions.
The augmented Lagrangian (AL) method that solves convex optimization problems with linear constraints has drawn more attention recently in imaging applications due to its decomposable structure for composite cost functions and empirical fast convergence rate under weak conditions. However, for problems such as X-ray co…
This work combines deep learning and sparse coding for CT image reconstruction.
Limited angle CT reconstruction is an under-determined linear inverse problem that requires appropriate regularization techniques to be solved. In this work we study how pre-trained generative adversarial networks (GANs) can be used to clean noisy, highly artifact laden reconstructions from conventional techniques, by …
Attenuation correction is an essential requirement of positron emission tomography (PET) image reconstruction to allow for accurate quantification. However, attenuation correction is particularly challenging for PET-MRI as neither PET nor magnetic resonance imaging (MRI) can directly image tissue attenuation properties…
Recent years have witnessed growing interest in machine learning-based models and techniques for low-dose X-ray CT (LDCT) imaging tasks. The methods can typically be categorized into supervised learning methods and unsupervised or model-based learning methods. Supervised learning methods have recently shown success in …
Medical imaging is playing a more and more important role in clinics. However, there are several issues in different imaging modalities such as slow imaging speed in MRI, radiation injury in CT and PET. Therefore, accelerating MRI, reducing radiation dose in CT and PET have been ongoing research topics since their inve…
New spatiotemporal Besov process improves CT image reconstruction and other inverse problems.
Bayesian method uses deep learning prior for CT reconstruction.
A neural network learns a convex regularizer for better image reconstruction.
The field of medical image reconstruction has seen roughly four types of methods. The first type tended to be analytical methods, such as filtered back-projection (FBP) for X-ray computed tomography (CT) and the inverse Fourier transform for magnetic resonance imaging (MRI), based on simple mathematical models for the …
Model estimates lung well-aerated volume from CT images, independent of patient and imaging parameters.
In this work we address the problem of real-time dynamic medical MRI and X Ray CT image reconstruction from parsimonious samples Fourier frequency space for MRI and sinogram tomographic projections for CT. Today the de facto standard for such reconstruction is compressed sensing. CS produces high quality images (with m…
Noise2Inverse removes artifacts in noisy CT images without needing clean data.
Model based iterative reconstruction (MBIR) algorithms for low-dose X-ray CT are computationally expensive. To address this problem, we recently proposed a deep convolutional neural network (CNN) for low-dose X-ray CT and won the second place in 2016 AAPM Low-Dose CT Grand Challenge. However, some of the texture were n…
Unlike previous works, this open data collection consists of X-ray cone-beam (CB) computed tomography (CT) datasets specifically designed for machine learning applications and high cone-angle artefact reduction. Forty-two walnuts were scanned with a laboratory X-ray set-up to provide not only data from a single object …
A new unsupervised method removes CT metal artifacts using beta-CycleGAN and attention.
Computed tomography for region-of-interest (ROI) reconstruction has advantages of reducing X-ray radiation dose and using a small detector. However, standard analytic reconstruction methods suffer from severe cupping artifacts, and existing model-based iterative reconstruction methods require extensive computations. Re…
Computed Tomography (CT) reconstruction is a fundamental component to a wide variety of applications ranging from security, to healthcare. The classical techniques require measuring projections, called sinograms, from a full 180 view of the object. This is impractical in a limited angle scenario, when the viewi…
Deep Learning approaches for solving Inverse Problems in imaging have become very effective and are demonstrated to be quite competitive in the field. Comparing these approaches is a challenging task since they highly rely on the data and the setup that is used for training. We provide a public dataset of computed tomo…
In sparse-view Computed Tomography (CT), only a small number of projection images are taken around the object, and sinogram interpolation method has a significant impact on final image quality. When the amount of sparsity (the amount of missing views in sinogram data) is not high, conventional interpolation methods hav…
Interior tomography for the region-of-interest (ROI) imaging has advantages of using a small detector and reducing X-ray radiation dose. However, standard analytic reconstruction suffers from severe cupping artifacts due to existence of null space in the truncated Radon transform. Existing penalized reconstruction meth…
Computer-Aided-Diagnosis (CADx) systems assist radiologists with identifying and classifying potentially malignant pulmonary nodules on chest CT scans using morphology and texture-based (radiomic) features. However, radiomic features are sensitive to differences in acquisitions due to variations in dose levels and slic…
Generative models solve medical imaging inverse problems without needing paired data.
CT-OT Flow estimates continuous-time dynamics from discrete snapshots.
Signal models based on sparsity, low-rank and other properties have been exploited for image reconstruction from limited and corrupted data in medical imaging and other computational imaging applications. In particular, sparsifying transform models have shown promise in various applications, and offer numerous advantag…
Study assesses CNN model robustness to noise in low-cost CT scans.
Stochastic image reconstruction is a key part of modern digital rock physics and materials analysis that aims to create numerous representative samples of material micro-structures for upscaling, numerical computation of effective properties and uncertainty quantification. We present a method of three-dimensional stoch…
Neural Optimal Design of Experiments improves inverse problem solving efficiency.
Diagnostic stroke imaging with C-arm cone-beam computed tomography (CBCT) enables reduction of time-to-therapy for endovascular procedures. However, the prolonged acquisition time compared to helical CT increases the likelihood of rigid patient motion. Rigid motion corrupts the geometry alignment assumed during reconst…
Conebeam CT using a circular trajectory is quite often used for various applications due to its relative simple geometry. For conebeam geometry, Feldkamp, Davis and Kress algorithm is regarded as the standard reconstruction method, but this algorithm suffers from so-called conebeam artifacts as the cone angle increases…
Let $\cT$ be Teichmüller space of a closed surface of genus at least 2. For any point $c\in \cT$, we describe an action of the circle on $\cT\times \cT$, which limits to the earthquake flow when one of the parameters goes to a measured lamination in the Thurston boundary of $\cT$. This circle action shares some of the …
A new COVID-19 CT dataset helps develop AI diagnosis models.
The last decade has shown a tremendous success in solving various computer vision problems with the help of deep learning techniques. Lately, many works have demonstrated that learning-based approaches with suitable network architectures even exhibit superior performance for the solution of (ill-posed) image reconstruc…
Pulmonary embolisms (PE) are known to be one of the leading causes for cardiac-related mortality. Due to inherent variabilities in how PE manifests and the cumbersome nature of manual diagnosis, there is growing interest in leveraging AI tools for detecting PE. In this paper, we build a two-stage detection pipeline tha…